In this episode, Graham and Ashkahn share their expert opinion on… bubbles.

Not just any bubbles, but the ones that you sometimes find in a tank while you’re floating. What causes that?

Show Resources

Listen to Just the Audio

Transcription of this episode… (in case you prefer reading)

Graham: Our question for today is: “lately, I’ve noticed small bubbles tickling me during my floats. They also seem to be forming on the floor of the tank. What is going on?”

Ashkahn: What is going on, huh?

Graham: Alright, well, “Bubbly in the U.S.” We’ve got a solution for you.

Ashkahn: We sure do. It sounds, to me, like you’re using hydrogen peroxide.

Graham: If I were to guess, I would say the same thing. Or, you’ve got an aerator hooked in to the bottom of your tank.

Ashkahn: Yeah. Which I suspect, it’s not the second one.

Graham: I’ve never seen that ever in my life before.

Ashkahn: Are you in a jacuzzi and not a float tank? Is that what’s going on here? Basically, hydrogen peroxide breaks down into oxygen and water when it’s reacting with stuff. If you have a lot of hydrogen peroxide in your float tank, you might start being able to actually notice those … the air being created from that breakdown process of the peroxide. That’s, basically, what you’re feeling. You’re feeling tiny, air bubbles from the hydrogen peroxide.

Graham: And, for us, we end up getting that effect in our float tanks when we get above or around 100 parts per million.

Ashkahn: Yeah, somewhere in that … like 100, 110. That’s the range where we start to notice the bubble issue.

Graham: That’s as measure by the old Taylor Drop Test Kit, K-1826.

Ashkahn: Which, has been verified to be accurate in float tank water.

Graham: Which, you can look up. Taylor Labs actually tested our float water after we harassed them for a long time. You might find that those parts per million are different if you’re using test strips, or something else. Also, if you are, I highly recommend switching over to the old K-1826.

Ashkahn: Basically, that. Just don’t put your peroxide to those levels. Drop lower than that, and you won’t see those bubbles.

Graham: And that said, I still, occasionally, get bubbles, even when we’re within regular hydrogen peroxide levels. But, it’s not bubbles tickling your back, I’ll just, occasionally, feel them forming on my back, or something came up and I just have one bubble that’s caught and tickling me. I don’t think that’s even that out of the ordinary.

Ashkahn: It’s way more subtle. This is almost continuous while you’re floating. You’re feeling these things, if your levels are too high.

Graham: If you bring it up to 400, 500 parts per million, accidentally, one of your staff drops way too much in there … sometimes, you can actually even see the bubbling in the water itself, visually, which is kind of interesting. Looks like little cauldron brew, or something, in there.

Ashkahn: So, don’t do that.

Graham: Another question, “Is that unsafe?” Are the bubbles a sign that your skin is being eaten by the hydrogen peroxide, or anything crazy like that?

Ashkahn: Not really, that I know of. The other thing that can happen with these levels of peroxide is, you can, very slightly, start to bleach people’s hair, which is another issue. Those are the main reasons people don’t want to go above these 100 limits. I don’t really know, I can’t really speak authoritatively on this, but, people are buying three percent hydrogen peroxide in those brown bottles from the grocery store and gargling with them, and putting them on wounds. Three percent is 30 thousand parts per million, is what that is. I think, even the highest thing I’ve heard tested was 1000 parts per million, and that didn’t seem to do damage to people. But again, don’t take my word for it. It, at least, seems anecdotally out there. It’s not like 100 is a danger zone when these bubbles are forming. I have not heard anything about that actually being a point where this would be harmful to your skin or even if you got it in your eyes, necessarily.

Graham: No real damage that we’ve been able to assess anywhere. As far as we can tell, this is actually the most negative byproduct you get, is, little bubbles and bleaching of the hair.

Ashkahn: Yeah, around that range. That’s why most people stop there. There’s not really … also, as far as I can tell, doesn’t seem like you get a huge benefit from having hydrogen peroxide levels much higher than that. Seems like their ability to oxidize and do the things that they’re doing peter off around 40, 50, 60 parts per million, something like that. You’re not getting a huge bang for your buck by dumping a ton of peroxide into the water.

Graham: Is there anything else that we think is likely to be causing bubbles in someone’s tank? I was trying to think of that while we were talking, and thinking and talking is hard. I decided to do one at a time.

Ashkahn: The bubbles, tiny bubbles, as you’re floating, or something like that, is almost always hydrogen peroxide. The other thing that can cause bubbles is a small leak in your filtration system, right? If you have a pinhole leak in your union. Then when you run your filtration system. Or if your water levels are too low, and your filtration system is sucking air in as you run it … But, that’s real obvious. You run your filtration system, all of a sudden, your whole float tank’s cloudy. It’s been chopped up like a blender, and it gets sent back in. That dissipates pretty quickly, too.

Graham: That’s a problem at the beginning of the float, but not something that would be ongoing. They even say, “small bubbles.”

Ashkahn: Visually, those are so different. Tiny bubbles that are persistent in the water during your float, versus, your whole float tank turns cloudy white for 10 minutes.

Graham: Alright. So, answered?

Ashkahn: I guess so.

Graham: Alright. And that’s our solution for today.

Ashkahn: We’ll talk to you tomorrow.

Graham: Thanks, everyone.

Recent Podcast Episodes

Tips for filling an empty service schedule – DSP 90

Tips for filling an empty service schedule – DSP 90

There are fewer things more stress inducing for a float center than seeing their schedule for the week and having it just be completely empty (Maybe watching your pump start up and spray water over your entire float room, but it’s a close call). What do you do in that situation? And how do you prevent it from happening in the future? 

Well, Graham and Ashkahn have tried everything, from doing shout outs and deals on social media, to literally walking down the street trying to convince people to come in and float while the tanks were empty. Some tactics are more effective than others, but what it really comes down, at least in Float On’s case, is being prepared to give out a ton of free floats.

The guys talk about the effectiveness of each strategy they’ve tried and  how they’ve reached out to contacts to form mutually beneficial business relationships and really get the ball rolling with filling up their tanks. 

Tips for filling an empty service schedule – DSP 90

pH testing devices for float tank solution – DSP 89

There are lots of things you can measure when testing the quality of your water, for sanitation and comfort. Many of which aren’t specifically designed for float tanks. This is kind of an open secret in the industry, but most things simply aren’t accurate because of the incredibly high salinity of float tank solution. And pH seems to be one of them. This can cause float center owners major headaches as it’s often one of the first things that health departments/regulators will want to measure when they come and inspect your place (if they do at all). 
Graham and Ashkahn try to break down this mystery of float water and try to break down some theories as to why it might be that float tank water might not have accurate pH readings, regardless of how you measure it. 

Tips for filling an empty service schedule – DSP 90

Handling humidity to reduce water drops on tank ceilings – DSP 88

One of the biggest Float Mysteries in the industry is how to properly deal with condensation in a float tank. Your float tank is basically a giant humidity generating machine so clearly there’s going to be some condensation, but how much and why it forms can vary for seemingly no reason, making managing it difficult. The last thing any float center owner wants is for it to affect the floats they’re running (little water droplets falling on floaters is no fun).

Graham and Ashkahn commiserate with the industry about the difficulties in dealing with this particular hot topic, while also delving into the science of it and common solutions that should help any float center owner that’s facing this problem. 

Tips for filling an empty service schedule – DSP 90

The purpose of a flow meters and the flow rate for a float tank – DSP 87

When navigating demands from health departments, it can be an absolute minefield of regulation, oftentimes with holdovers from the pool and spa industries. Many of these can be superfluous to float centers, but if you’re just starting a center, it’s difficult to know which ones to ignore, and which ones to incorporate.

Flow meters fall into this weird gray area where they’re not as important for float centers as for pools (and in some cases aren’t really needed at all), but can still be required by health departments or regulators. And to not throw the baby out with the salty bathwater, there are definitely some very practical uses for flow meters on float tanks. 

Graham and Ashkahn tackle all these confusing elements and even provide specific product recommendations for flow meters for float tanks. Give it a listen!

Tips for filling an empty service schedule – DSP 90

When to contact health department – DSP 86

Contacting your health department/inspector/regulator/enforcer/supreme overlord can be stressful, to say the least. And given their general lack of understanding of floating as an industry, it makes sense why float centers may put this off. However, they have the authority to shut down your business if they feel that it’s a public safety issue, and that’s a situation no one should put themselves in. 

Talking to your health department early and often can save yourself some headaches, but you don’t want to go to them unprepared. There’s a lot of nuance to regulation and existing codes that you should probably be familiar with beforehand. Fortunately, it may be something other float centers in your area have had to deal with, if there are any. 

Ashkahn and Graham have a few tips for what to do to prepare and how to address common concerns they may have in this episode. 

Latest Blog Posts

No Results Found

The page you requested could not be found. Try refining your search, or use the navigation above to locate the post.