Ashkahn is currently recovering from his talk and the after-party last night, but Jake and Graham have gracefully taken the time to answer a construction question again today.

On the docket today is a question about wiring a float tank directly into the wall. Graham and Jake provide an overview of why some people may prefer this (it’s much easier to keep waterproof, e.g.), and why at Float On they use the twist lock for their outlets and how to properly utilize them.

Show Resources

Today is the last day of the Float Conference! Go to Floatconference.com for info on speakers and scheduled events! 

More information on twist locks and how they’re used

Leviton Twist Locks (Woodward Twist Locks are functionally identical if you come across those instead)

Listen to Just the Audio

Transcription of this episode… (in case you prefer reading)

Graham: All right. Hello everybody.

Jake: Hey, hey everybody. Ahoy. Ahoy.

Graham: I am Graham.

Jake: And I am Jake.

Graham: And we are continuing in the vein of construction questions we’ve been doing while Ashkahn away from the mic. Today’s is, “should I wire my tanks into the wall?”

Jake: Well, depending on how much power they draw, in some places you may be required to.

Graham: Yep, so you might not even have a choice.

Jake: Yeah.

Graham: Which makes the decision really easy.

Jake: Yeah.

Graham: Just, yeah. Don’t do it and skate under the radar. Simple.

Jake: Never ever ever do that.

Graham: Jake won’t even let me joke about it.

Jake: But if you can, if you do have the option and you’re allowed to not have your tanks hardwired in, we prefer not to have them hardwired in. We like to use a twist lock plug into the wall. That way it doesn’t back out. You know worst case scenario, the pumps turning off and on, that plug backs out a little bit. One of my staff are running through the room picking up like a float pillow or something like that. They look over, see it, and then they reach out and grab and shock themselves. We don’t want that. But we do want to be able to move things around. If want to take the tank out of the room, do a remodel or something like that, it’s easier to just unplug something than having an electrician come in and have to take it out of the wall for you.

Graham: Yeah, and I guess let’s explain what a twist lock is, and the different options for it.

Jake: Right.

Graham: So twist lock into the wall is different than a twist lock into kind of a corded plug.

Jake: Yeah, umbilical. Yeah.

Graham: But the mechanism is the same, which is basically instead of just plugging something in, they’re creating this gasket and sort of a water tight seal, and actually doing a little twist lock into making sure water can’t get in there.

Jake: And you have a couple choices here. You can either twist lock directly into the wall outlet, which is what we recommend. Or you can get two ends of a plug, an umbilical basically, sticking out of the wall, and then those twist lock together.

Graham: We used those for quite a while.

Jake: Yeah.

Graham: That was one of our go-tos. Over the years we’ve just seen them fail. You know not once but a handful of times.

Jake: You’ve gotten moisture in them. The ones that still exist at float on, we actually wrap them with silicon as well.

Graham: Yeah. I’m not sure if it’s when you first go to plug them in and they just had a little salt, they weren’t quite cleaned enough or whether, yeah, wicked in there, which I almost doubt.

Jake: I don’t know.

Graham: Yeah, I don’t know.

Jake: I think it’s we don’t know.

Graham: They failed and so we’re less keen on those now.

Jake: I think humidity’s building up inside there. Just enough to cause it to short out a little bit. Like it doesn’t fail catastrophically. We’ll just notice and all of a sudden there will be a smell and the plug is on its way to burning out. That’s when we kill all the power to everything.

Graham: Yeah, then you open it up and it’s definitely singed on the inside. Like it’s a little scary when you see that, understandably.

Jake: We’re in kind of a crazy environment, right? We’re using these tanks. They’re full of water. We’re connecting them to a power source. Like electricity’s kind of a scary thing.

Graham: We should say it’s crazy that even these things that are meant to be totally watertight and gasket together, those fail in our space. Again, it’s just a reason that we use the wall gasketing plugs.

Jake: Yeah, the twist locks into the wall. Something else-

Graham: Do we have a name brand for people that we recommend for people?

Jake: We use Leviton a few times. We’ve also used, I believe, Woodward as well. Both of them operate just pretty much the same.

Graham: Yeah.

Jake: Something else we consider is actually that tail connecting to your tank, that cord. We’ll have our swapped out with a SO cord. It’s an outdoor rated cord just because that can live in a wet environment. Whereas like your regular household lamp cord, that could fail over time. Basically, just has a much larger protective sheath around it, so you can never nick it or anything like that.

Graham: Yeah, I guess the benefits of, again, being able to unplug your tank at any given time is you can take it out to do maintenance, you can, if the plug is attached to the brains of the tank or the controller in the room, you can theoretically unplug that and move it and do repairs on that without having to un-hardwire to from the wall. Basically, a lot more flexibility. A lot more room for maintenance and repair without needing to do the work of actually unwiring something that’s directly hardwired into the building.

Jake: Because that’s a contractor’s job. I know it seems simple. You can undo three wires, but you really don’t want to mess with anything like that. Anything that’s wired in, connects to the grid, bring an electrician in, a licensed, bonded electrician.

Graham: And the reason is just even though it is simple, you might’ve even done repairs around your house or any number of different scenarios with electricity, but if your building were to catch on fire, if there were this accident electrically and you’ve done some electrical work that wasn’t done by a licensed electrician, all of a sudden who

Jake: Your claim might be denied.

Graham: Yeah, who’s on the spot.

Jake: Liability. Yeah. Insurance company’s not going to be happy about that. That’s for sure.

Graham: And if it could be traced back to anywhere near where you did the electrical work, then that speaks very poorly towards your chances of getting money out of that all of a sudden. That’s why it’s more just for protection in case the worst happens more than anything else. Not like we’re saying you can’t do it or anything like that.

Jake: Yeah, again, relatively simple but just hire somebody else to do it.

Graham: I get totally derailed on insurance side of things.

Jake: I’m scared of electricity.

Graham: Oh, so the upside of having it hardwired directly into the wall is, like we’re talking about, you know moisture getting in there or issues arising. I mean that’s pretty much eliminated for the most part.

Jake: Yeah, because that cord then goes into a junction box that you can have moisture-proof junction box and everything’s connected inside there. It has gaskets.

Graham: Yeah, yeah. You can really just eliminate that worry. Even with having a cord that is this gasket system that goes into a wall, there is still a chance that the part of the cord that’s going into the wall has some moisture on it or a little salt or same, you know, a drop splashed onto the wall at that point. Even though they’re high up off the ground, and now all of a sudden you can have a short. I don’t know. For peace of mind I would say is one of the things that-

Jake: For sure, peace of mind. I would add one more note here just on the placement of those actual junction boxes, those outlets. You know we want those high and tight. You know what I mean? Like we don’t want those down in the spray area where you’re priming your system or whatever you’re going to be spraying water all over the place. We’ve seen leaks develop in pretty much every single spa pack. Like there’s no spa pack that has not suffered a leak at least at one point in time. Either from a ball joint failing or from even, we saw a pinhole in some flex tubing. It just was shooting straight out several feet and one little stream of water. So, yeah, we really try to keep electricity as far as we possibly can away from clients and away from any wet zones.

Graham: Cool. Yeah, as to whether or not you should wire your tank into a wall, there are pros and cons on either side. For us, personally, we like, again, having the very protected outdoor certified gasket system that goes into the wall directly. For other people, you may be required to have it in the wall or you may just like the safety of it. There’s no right or wrong here is, I guess, what I’m getting down to. Oh, there is a wrong. The wrong is to just have, in my mind, your tank just plugged directly into wall.

Jake: No outlet even? Just like bare wires? Like that might not be the safest.

Graham: Just bare wires.

Jake: That might not be the safest.

Graham: Okay, so there are wrong answers, but maybe no absolute right answer.

Jake: One more note on us tanking our tanks out of our rooms. Keep in mind we are open 24 hours a day, so we do break down our tanks and do some deep cleaning on them and replace caulk lines and things like that. Or if we need to repair flooring in a room, it’s easier to get that tank out of the room. So we definitely break our tanks down from time to time.

Graham: Unfortunately, because it’s a huge hassle. Okay. If you have questions of your own, cruise on down to floattanksolutions.com/podcast.

Jake: All right. Thanks for having us.

Graham: Yep. Thanks everyone.

Recent Podcast Episodes

Being the First Float Center – DSP 320

What’s it like to be the first float center to open in an area? How do you handle it? 

Graham and Ashkahn explain what it was like opening Float On, being one of the first dedicated float centers in the United States. The exciting thing is that creating awareness is really fun, but it can be a little stressful since your float center will represent floating as a practice for people.

Many of the tips here are the same for anyone opening a center: focus on awareness, be prepared to educate, and make sure your floats are the best they can be.

What you Need to Know About Algorithms – DSP 318

Ashkahn and Derek talk about algorithms, those pesky bits of code that push your posts up or down on social media and search engines and leave you scrambling for ways to get likes and clicks, constantly mixing it up to just be seen. 

The duo discusses how algorithms affect everyday posts for small businesses and how to keep up on information about the constantly changing nature of these systems. The main takeaway is, if your content is fresh, non-repetitive and you aren’t trying to game the system, you likely have nothing to worry about.

Commissions for Memberships? – DSP 317

Any sales related business knows that commissions are the gold-standard incentive program for drumming up business, but how does it work in a float center for memberships?

Derek and Ashkahn talk about the mixed success they’ve experienced at Float On each time it’s been tried. 

Getting Members to Float More Often – DSP 316

Single float memberships have become increasingly more common in the float industry, typically with the option to purchase additional floats for the month at a discount. But how do you properly incentivize those members to float more than a single time per month? 

Ashkahn and Derek talk marketing tips to keeping your float center top of mind and making sure your members are active regularly. 

Latest Blog Posts

How Many Float Tanks Should I Have?

How Many Float Tanks Should I Have?

Intro If you’ve crossed over into the sacred realm of “Yeah, I’m pretty sure I’m gonna open up a float center,” an obvious question arises — “How many tanks should I have?” Now, if you’re like me, you’re creating a 90 tank float community where everyone who buys in...

The Construction Secret to Soundproofing: Storage Between Float Rooms

The Construction Secret to Soundproofing: Storage Between Float Rooms

If you’ve ever taken a look at our construction materials or gotten advice on soundproofing, you’ve probably heard of the importance of including “air gaps” when building out your center. What that means and why it helps can be a bit of a technical question, and the practical implementation can seem daunting and unreasonable.  

Float Conference 2017 Recap

Float Conference 2017 Recap

Now that the salt has settled, I’m sharing some thoughts from “The Great Gathering of People Who Really Love Being Alone Sometimes in a Dark, Briny Room,” also known as The Float Conference.

The conference has always been an amazing opportunity to connect with the pulse of the broader float industry and, if this year’s gathering showed us anything, it’s that our collective heartbeat is as strong as ever.

2017 Float Conference Program Introduction

2017 Float Conference Program Introduction

Every year, I have the great pleasure of writing the introduction for the Float Conference program, and every year we share it on our blog so that members of the industry who weren’t able to make the journey out to Portland are able to check it out. I hope you enjoy reading it as much as I enjoyed writing it.

From all of us at Float Tank Solutions, where our time is measured as the space between two conferences, thank you again for a wonderful year!

– Graham Talley